 OPERATE SEQUENCES
SEQUENCES:
Allows an operator to see a routine of camera views on any system monitor,
repeatedly. The sequence can be operated automatically or manually. The
order in which the camera views appear and the time each view remains can
be programmed.
The DLH4200B SERIES provides two types of sequences, eight programmable
sequences and one unprogrammable sequence. If you select the fixed
sequence type, the camera views switches according to their serial number
(ascending/descending), without programming . Monitor screen show SEQ00 ,
fresh time interval set to 10 seconds, no PTZ operating and Replay controlling;
If you select the programmable sequence type, access the menu for
configuration, steps switching and time spacing. Refer to the following table
for detailed instructions and options. Monitor screen show SEQ0108. You can
select the camera numberPTZ operating and Replay controlling.
When the sequence run, top-right of monitor will show "SEQ01", indicate that
the No.01 sequence is operating.
Run sequence switching
Select monitor, for fixed sequence, press and hold NEXT key or
PREV key. For program sequence, enter the serial number (1~8), then
press and holdNEXTkey or PREVkey.
NEXTkey: The camera views switches according to their ascending serial
number from one to sixty-four . Just like step one step two step
three……Step sixty-four.
PREVkey: The camera views switches according to their descending serial
number from sixty-four to one. Just like step sixty-fourstep sixty-three
step sixty-two……Step one.
Runtime sequence
When running sequence, you can carry out step-jumping or changing step by
navigating keyboard.
PressNEXTkey, skip current step and jump to the next step.
PressPREVkey, skip current step and jump to the last step.